| DEVICE | UMTS (Subscriber Station) | 
    
        | REGULATION | DG DECREE NUMBER 5 YEAR 2019 | 
    
        | ETSI | EN301908-1 | 
    
        | ETSI | EN301908-2 | 
    
        |  |  |  | 
    
        | NR. | TEST ITEM | LIMIT | 
    
        | 1 | Frequency Range (Radio Frequency Band) | 
                
                    | Band 3GPP | Frequency Uplink SS (Tx) − BS (Rx)
 | Frequency Downlink SS (Rx) − BS (Tx)
 |  
                    | I | 1920 − 1980 MHz | 2110 − 2170 MHz |  
                    | VIII | 880 − 915 MHz | 925 − 960 MHz |  | 
    
        | 2 | Channeling | 
                
                    |  | UARFCN | Frequency |  
                    | Uplink | Nu = 5* (FUL − FUL_OFFSET) | FUL_low ≤ FUL ≤ FUL_high |  
                    | 9612 to 9888 MHz | 1922.4 to 1977.6 MHz |  
                    | Downlink | ND = 5* (FDL − FDL_OFFSET) | FDL_low ≤ FDL ≤ FDL_high |  
                    | 10562 to 10838 MHz | 2112.4 to 2167.6 MHz |  | 
    
        | 3 | Maximum Channel Power | 
                
                    | Operating Band | Power Class 1 | Power Class 2 | Power Class 3 | Power Class 4 | Power Class 5 |  
                    |  | Power (dBm) | Tol*) (dB) | Power (dBm) | Tol*) (dB) | Power (dBm) | Tol*) (dB) | Power (dBm) | Tol*) (dB) | Power (dBm) | Tol*) (dB) |  
                    | Band I | +33 | +1/-3 | +27 | +1/-3 | +24 | +1/-3 | - | - | +21 | +2/-2 |  *) Tol = Tolerance | 
    
        | 4 | Frequency Error | ±0.01 ppm | 
    
        | 5 | Spurious Emission | 
                
                    | Frequency Bandwidth | Measurement Bandwidth | Minimum Requirement |  
                    | 9 kHz ≤ f < 150 kHz | 1 kHz | -36 dBm |  
                    | 150 kHz ≤ f < 30 MHz | 10 kHz | -36 dBm |  
                    | 30 MHz ≤ f < 1000 MHz | 100 kHz | -36 dBm |  
                    | 1 GHz ≤ f < 12.75 GHz | 1 MHz | -30 dBm |  | 
    
        | 6 | Sensitivity | 
                
                    | Operating Band | Unit | DPCH_Ec[REFSENS] | [REFIor] |  
                    | I | dBm / 3.84 MHz | -117 | -106.7 |  
                    | Note 1: For power class 3 and 3bis shall be at the maximum output power Note 2: For power class 4 this shall be at the maximum output power
 |  | 
    
        | 7 | Emission Mask | 
                
                    | Δf in MHz (Note 1) | Minimum Requirement (Note 2) | Measurement Bandwidth |  
                    | Relative Requirement | Absolute Requirement |  
                    | 2.5 − 3.5 | {-35-15.((Δf/MHz)-2.5)}dBc | -71.1 dBm | 30 kHz (Note 3) |  
                    | 3.5 − 7.5 | {-35-1.((Δf/MHz)-3.5)}dBc | -55.8 dBm | 1 MHz (Note 4) |  
                    | 7.5 − 8.5 | {-39-10.((Δf/MHz)-7.5)}dBc | -55.8 dBm | 1 MHz (Note 4) |  
                    | 8.5 − 12.5 | -49 dBc | -55.8 dBm | 1 MHz (Note 4) |  Note 1: Δf is the separation between the carrier frequency and the centre of the measurement bandwidth. Note 2: The minimum requirement is calculated from the relative requirement or the absolute requirement, whichever is the higher power. Note 3: The first and last measurement position with a 30 kHz filter is at Δf equals to 2.515 MHz and 3.485 MHz. Note 4: The first and last measurement position with a 1 MHz filter is at Δf equals to 4 MHz and 12 MHz | 
    
        | 8 | Occupied Bandwidth (OBW) | ≤ 5 MHz (OBW < 5 MHz) | 
    
        | 9 | Adjacent Channel Leakage Power Ratio (ACLR) | 
                
                    | Power Class | Adjacent Channel Frequency Relative to Assigned Channel Frequency
 | ACLR Limit |  
                    | 3 | +5 MHz or -5 MHz | 33 dBm |  
                    | 3 | +10 MHz or -10 MHz | 43 dBm |  
                    | 4 | +5 MHz or –5 MHz | 33 dBm |  
                    | 4 | +10 MHz or -10 MHz | 43 dBm |  | 
    
        | 10 | Power Supply | SS (Subscriber Station) operating with SELV (Safety Extra Low Voltage) in an environment that allows overvoltage of the telecommunications network. SELV refers to a voltage that does not exceed 42.4 V peak or 60 V DC |